Monitored flow and water quality data from upper river taw observatory in 2018 and 2019 water years
As part of the delivery for a strategic research programme, Soil to Nutrition, a multi-scale landscape observatory - the upper River Taw observatory (URTO, https://www.rothamsted.ac.uk/project/upper-river-taw-observatory-urto) has been established in a landscape with mixed land use to support the integration of science, stakeholder engagement and policy support. 15-minute resolution data have been collected from 3 nested catchments, namely: Upper Ratcombe, Lower Ratcombe and Pecketsford, using multi-parameter sensors. These sensors cover river flow (water level, flow velocity, discharge) and physiochemical parameters (temperature, pH, turbidity, pH, conductivity, ammonium and nitrate). The recorded data have been visually inspected and assessed based on expert judgement with built-in instrument logs. Data considered to be erroneous were removed and each data point has been assigned a quality assurance code to assist the appropriate use of the data. Ultimately, the user of the data must assess the data they are using according to the context in which they wish to use it. Separate image files in British National Grid Reference (NGR) are also provided for mapping the catchment boundaries.
| Item Type | Data Collection |
|---|---|
| Creators | Granger, Steve, Zhang, Yusheng, Sint, Hadewij, Collins, Adrian |
| Keywords | water quality; monitoring; watersheds; England |
| Project | S2N - Soil to Nutrition - Work package 3 (WP3) - Sustainable intensification - optimisation at multiple scales |
| Date | 25 March 2022 |
| Temporal coverage |
From To 8 October 2018 1 April 2020 |
| Geographic coverage | -3.979,50.655,-3.875,50.783 |
| Data collection method | At 3 catchment monitoring sites a stilling well was installed to house a multi-parameter sonde (YSI, Xylem Inc Rye Brook, New York, U.S). The sondes hold five sensors which measure multiple water quality parameters; temperature, specific conductivity, turbidity, and ion selective electrodes for nitrate-N (NO3-), ammonium-N (NH4+) and pH. Instruments were returned to the laboratory every month for cleaning, assessment and recalibration. Performance logs were made of the equipment to assess the quality of the data collected, and whether sonde instruments needed replacing. Instrument measurements are controlled, and data recalled via Adcon (ADCON, Austria) remote telemetry units (RTUs) using UHF radio every 15-minutes. A base-station (A850 Gateway) manages the RTUs which collect in-field data every 15-minutes. The central base-station ensures that measurements across the 3 sites are conducted at the same time and time stamped accordingly. Software (AddVantage Pro) collects, stores and displays the data via an integrated web server and an extension running within the software automatically creates and exports weekly CSV files for each parameter for archiving and further data processing. |
| Publisher | Rothamsted Research |
| Digital Object Identifier (DOI) | 10.23637/rothamsted.9882v |
-
subject - Other
-
- Available under Creative Commons: Attribution 4.0
grid_on - application/vnd.openxmlformats-officedocument.spreadsheetml.sheet
- folder_info
- 14MB
-
subject - Other
-
- Available under Creative Commons: Attribution 4.0
grid_on - application/octet-stream
- folder_info
- 42kB
-
subject - Other
-
- Available under Creative Commons: Attribution 4.0
grid_on - application/octet-stream
- folder_info
- 6kB
-
subject - Other
-
- Available under Creative Commons: Attribution 4.0
grid_on - application/octet-stream
- folder_info
- 2kB